TY - JOUR
T1 - Clinical application of whole-genome array CGH during prenatal diagnosis
T2 - Study of 25 selected pregnancies with abnormal ultrasound findings or apparently balanced structural aberrations
AU - Evangelidou, Paola
AU - Sismani, Carolina
AU - Ioannides, Marios
AU - Christodoulou, Christodoulos
AU - Koumbaris, George
AU - Kallikas, Ioannis
AU - Georgiou, Ioannis
AU - Velissariou, Voula
AU - Patsalis, Philippos C.
PY - 2010
Y1 - 2010
N2 - Abstract. Background. The purpose of the study was the application and evaluation of array Comparative Genomic Hybridization (array CGH) in selected cases during prenatal diagnosis. Array CGH was applied in 25 fetal samples out of which 15 had normal karyotypes and abnormal ultrasound findings and 10 had apparently balanced structural aberrations with or without abnormal ultrasound findings. DNA was extracted from peripheral blood, chorionic villi samples (CV) and amniotic fluid. Bacterial Artificial Chromosome (BAC) array CGH (Cytochip, BlueGnome Ltd.) of 1 Mb was applied and results were confirmed with either Fluorescence In Situ Hybridization (FISH), Multiplex Ligation-dependant Probe Amplification (MLPA) or Real-Time PCR. Results. Three out of 25 samples (12%), referred for prenatal array CGH, were found to carry copy number alterations. The number of cases with clinically significant alterations was 2/25 (8%), while one (4%) was of uncertain clinical significance. Two benign Copy Number Variations (CNVs) were also found in 1/25 cases (4%). Conclusions. The outcome of this study indicates the ability of array CGH to identify chromosomal abnormalities which cannot be detected during routine prenatal cytogenetic analysis, therefore increasing the overall detection rate.
AB - Abstract. Background. The purpose of the study was the application and evaluation of array Comparative Genomic Hybridization (array CGH) in selected cases during prenatal diagnosis. Array CGH was applied in 25 fetal samples out of which 15 had normal karyotypes and abnormal ultrasound findings and 10 had apparently balanced structural aberrations with or without abnormal ultrasound findings. DNA was extracted from peripheral blood, chorionic villi samples (CV) and amniotic fluid. Bacterial Artificial Chromosome (BAC) array CGH (Cytochip, BlueGnome Ltd.) of 1 Mb was applied and results were confirmed with either Fluorescence In Situ Hybridization (FISH), Multiplex Ligation-dependant Probe Amplification (MLPA) or Real-Time PCR. Results. Three out of 25 samples (12%), referred for prenatal array CGH, were found to carry copy number alterations. The number of cases with clinically significant alterations was 2/25 (8%), while one (4%) was of uncertain clinical significance. Two benign Copy Number Variations (CNVs) were also found in 1/25 cases (4%). Conclusions. The outcome of this study indicates the ability of array CGH to identify chromosomal abnormalities which cannot be detected during routine prenatal cytogenetic analysis, therefore increasing the overall detection rate.
UR - https://www.scopus.com/pages/publications/78649326314
U2 - 10.1186/1755-8166-3-24
DO - 10.1186/1755-8166-3-24
M3 - Article
AN - SCOPUS:78649326314
SN - 1755-8166
VL - 3
JO - Molecular Cytogenetics
JF - Molecular Cytogenetics
IS - 1
M1 - 24
ER -