N2 - Dermabond (Ethicon Inc., Somerville, NJ, USA) is a cyanoacrylate adhesive normally indicated for skin wound closure. This study describes the emergency use of this adhesive to control bleeding close to coronary anastomoses in exceptional cases. Dermabond was used in 17 patients who underwent cardiac surgery during an eight-month period, where other haemostatic interventions were unsuitable. It was applied for haemorrhage in 15 patients and control air leaks in two of the patients. Haemostasis was successful with Dermabond alone in 11 patients; the remaining four required additional interventions. It effectively controlled haemorrhage from ventricular pacing wires, vascular sling holes, peri-anastomotic bleeding, and epicardial tears. The adhesive was not placed directly on any graft because of embolic risk. In the two patients with visible air leaks, it was successfully used. No patient events were recorded as a result of haemorrhage and no reported toxicity. Dermabond may be indicated in circumstances in which haemostasis with traditional methods has failed or is inappropriate. A need for further high-quality objective research exists on the effectiveness and long-term safety of 2-octyl cyanoacrylate in cardiac surgery.
AB - Dermabond (Ethicon Inc., Somerville, NJ, USA) is a cyanoacrylate adhesive normally indicated for skin wound closure. This study describes the emergency use of this adhesive to control bleeding close to coronary anastomoses in exceptional cases. Dermabond was used in 17 patients who underwent cardiac surgery during an eight-month period, where other haemostatic interventions were unsuitable. It was applied for haemorrhage in 15 patients and control air leaks in two of the patients. Haemostasis was successful with Dermabond alone in 11 patients; the remaining four required additional interventions. It effectively controlled haemorrhage from ventricular pacing wires, vascular sling holes, peri-anastomotic bleeding, and epicardial tears. The adhesive was not placed directly on any graft because of embolic risk. In the two patients with visible air leaks, it was successfully used. No patient events were recorded as a result of haemorrhage and no reported toxicity. Dermabond may be indicated in circumstances in which haemostasis with traditional methods has failed or is inappropriate. A need for further high-quality objective research exists on the effectiveness and long-term safety of 2-octyl cyanoacrylate in cardiac surgery.
UR - http://www.scopus.com/inward/record.url?scp=55349110558&partnerID=8YFLogxK
M3 - Article
C2 - 17429768
AN - SCOPUS:55349110558
SN - 1090-3941
VL - 16
SP - 46
EP - 51
JO - Surgical technology international
JF - Surgical technology international
ER -