TY - JOUR
T1 - The corridor effect in droplet and aerosol pathogens transmission
AU - Kokkinakis, Ioannis William
AU - Drikakis, Dimitris
N1 - Publisher Copyright:
© 2025 Author(s).
PY - 2025/3/1
Y1 - 2025/3/1
N2 - This study investigates the effect of natural ventilation on the distribution of airborne pathogens in narrow, low-ceiling corridors typical of hotels, offices, or cruise ships. Two scenarios are examined: a milder cough at 6 m/s and a stronger cough at 12 m/s. A reference baseline case with no airflow is compared to cases featuring an incoming airflow velocity of 1 m/s (3.6 km/h), examining differences in the dispersal of respiratory droplets from two individuals coughing spaced 5 meters apart. Both individuals cough in the direction of the airflow, assuming one-way traffic to minimize airborne pathogen transmission. Findings indicate that airflow accelerates past the door, exceeding 3 m/s, with gusts reaching 4 m/s due to interaction with recirculation zones. This acceleration affects droplet dispersal. Larger droplets (>150 μ m) maintain a ballistic trajectory, traveling 2-4 m, potentially increasing transmission risk but suggesting that a 5-m distancing policy could suffice for protection. Smaller droplets (<150 μ m), especially those <100μm, spread extensively regardless of cough strength while containing the most viral mass overall. Thus, distancing alone is insufficient. The study recommends that additional safety measures be enforced, such as wearing masks, stricter usage protocols for corridors by limiting corridor use to one person every 20-30 s, or eliminating natural ventilation when feasible to effectively mitigate transmission risks in such environments.
AB - This study investigates the effect of natural ventilation on the distribution of airborne pathogens in narrow, low-ceiling corridors typical of hotels, offices, or cruise ships. Two scenarios are examined: a milder cough at 6 m/s and a stronger cough at 12 m/s. A reference baseline case with no airflow is compared to cases featuring an incoming airflow velocity of 1 m/s (3.6 km/h), examining differences in the dispersal of respiratory droplets from two individuals coughing spaced 5 meters apart. Both individuals cough in the direction of the airflow, assuming one-way traffic to minimize airborne pathogen transmission. Findings indicate that airflow accelerates past the door, exceeding 3 m/s, with gusts reaching 4 m/s due to interaction with recirculation zones. This acceleration affects droplet dispersal. Larger droplets (>150 μ m) maintain a ballistic trajectory, traveling 2-4 m, potentially increasing transmission risk but suggesting that a 5-m distancing policy could suffice for protection. Smaller droplets (<150 μ m), especially those <100μm, spread extensively regardless of cough strength while containing the most viral mass overall. Thus, distancing alone is insufficient. The study recommends that additional safety measures be enforced, such as wearing masks, stricter usage protocols for corridors by limiting corridor use to one person every 20-30 s, or eliminating natural ventilation when feasible to effectively mitigate transmission risks in such environments.
UR - http://www.scopus.com/inward/record.url?scp=105000290428&partnerID=8YFLogxK
U2 - 10.1063/5.0263406
DO - 10.1063/5.0263406
M3 - Article
AN - SCOPUS:105000290428
SN - 1070-6631
VL - 37
JO - Physics of Fluids
JF - Physics of Fluids
IS - 3
M1 - 033362